Part Number Hot Search : 
15800 2SB1381 09012 LA5779MP 12F10M SG564420 CAT52407 LM7915CT
Product Description
Full Text Search
 

To Download D2FD-01L30-1H Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 d2fd dust proof ultra subminiature basic switch ultra subminiature and dust proof ? sealing by using rubber packing means the switch can be used in dust-proof environments (iec ip6x). ? switch rating of 2 a at 125 vac possible with a single-leaf movable spring. models for micro loads are also available. ? solder and pcb terminals are available. rohs compliant model number legend list of models contact form spdt ratings 2 a 0.1 a actuator terminals pin plunger solder terminals d2fd-2l0-1h d2fd-01l0-1h pcb terminals d2fd-2l0-1t d2fd-01l0-1t hinge lever solder terminals d2fd-2l1-1h d2fd-01l1-1h pcb terminals d2fd-2l1-1t d2fd-01l1-1t simulated roller lever (r2.5) solder terminals d2fd-2l30-1h D2FD-01L30-1H pcb terminals d2fd-2l30-1t d2fd-01l30-1t d2fd - @@ -1 @ 12 3 1. rating 2 : 2 a at 125 vac / 30 vdc 01 : 0.1 a at 125 vac / 30 vdc 2. actuater l0 : pin plunger l1 : hinge lever l30 : simulated roller lever 3. terminals h : solder terminals t : pcb terminals com no nc
2 d2fd dust proof ultra subminiature basic switch contact specifications note: for more information on the minimum applicable load, refer to using micro loads . ratings note: the rating values apply under the following test conditions. 1. ambient temperature: 20 2 c 2. ambient humidity: 65 5% 3. operating frequency: 20 operations/min characteristics note: 1. the data given above are initial values. 2. the dielectric strength shown in the table indicates a value for models with a separator. 3. for the pin plunger models, the above values apply for both the free position and total travel position. for the lever models, the values apply at the total travel position. contact opening or closing time is within 1 ms. 4. consult your omron sales representative for testing conditions. terminals (unit: mm) mounting holes (unit: mm) solder terminals item model d2fd-2 models d2fd-01 models contact specification crossbar material silver alloy gold alloy gap (standard value) 0.25 mm minimum applicable load (see note) 100 ma at 5 vdc 1 ma at 5 vdc model rated voltage d2fd-2 models d2fd-01 models resistive load 125 vac 2 a 0.1 a 30 vdc 2 a 0.1 a item model d2fd-2 models d2fd-01 models operating speed 1 mm to 500 mm/s operating frequency mechanical 120 operations/min max. electrical 20 operations/min max insulation resistance 100 m ? min. (at 500 vdc) contact resistance (initial value) 30 m ? max. 100 m ? max. dielectric strength (see note 2) 600 vac 50/60 hz 1 min between terminals of same polarity 1,500 vac 50/60 hz 1 min between current carrying metal parts and ground 1,500 vac 50/60 hz 1 min between each terminal and non-current carrying metal part vibration resistance (see note 3) malfunction 10 to 55 hz, 1.5 mm double amplitude shock resistance (see note 3) destruction 1,000 m/s 2 max. malfunction 300 m/s 2 max. durability (see note 4) mechanical 300,000 operations min. (at 60 ops./min.) electrical 30,000 operations min. (at 20 ops./min.) 100,000 operations min. (at 20 ops./min.) degree of protection ip6x ambient operating temperature ? 20 to +70 c (at 60%rh max.) (with no icing) ambient operation humidity 85%rh max. (for +5 to +35 c) weight approx. 0.7 g (pin plunger, pcb terminal models) solder terminals pcb terminals pcb mounting dimensions (reference) 1.5 2.4 dia. +0.1 ?0.05 0.5 1.7 2.5 0.1 1.2 0.4 12.8 0.15 5.08 0.15 5.08 0.15 4.8 0.1 4 5.7 2 4.4 6 2.2 2.4 +0.1 ?0.05 three, r0.8 1.25 0.12 1.5 0.12 1.1 0.12 0.4 0.9 two,1.2 dia. +0.12 0 5 0.15 5.5 6 4.4 1.5 0.1 3.15 6.5 0.1 5.08 0.15 5.08 0.15 12.8 0.15 1.6 5.08 0.1 three, 1.2 0.05 dia. 5.08 0.1 two, m2.3 4.8 0.1
3 d2fd dust proof ultra subminiature basic switch dimensions (unit: mm) / operating characteristics the following illustrations and drawings are for solder terminal models. pcb terminal models are omitted from the drawings. ref er to terminals for these terminals. when ordering, replace @ with the code for the rating that you need. for the combination of models, refer to list of models . note: 1. unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 2. the operating characteristics are for operation in the a direction ( ). pt 2.5 0.1 2.4 +0.1 ?0.05 1.2 dia. a 4.35 op 6.5 0.15 2.4 dia. +0.1 ?0.05 pin plunger models d2fd- @ l0-1h d2fd- @ l0-1t model d2fd- @ l0-1h d2fd- @ l0-1t of max. rf min. 2.00 n {204 gf} 0.25 n {25 gf} pt max. ot mix. md max. 0.6 mm 0.25 mm 0.12 mm op (-1h) op (-1t) 7.0 0.2 mm 7.0 0.3 mm hinge lever models d2fd- @ l1-1h d2fd- @ l1-1t model d2fd- @ l1-1h d2fd- @ l1-1t of max. rf min. 0.65 n {66 gf} 0.05 n {5 gf} ot mix. md max. 0.5 mm 0.5 mm fp max. op (-1h) op (-1t) 11.3 mm 8.3 1.0 mm 8.3 1.2 mm t = 0.3 stainless-steel lever a op fp 6.5 0.15 3 5.25 simulated roller lever models (r2.5) d2fd- @ l30-1h d2fd- @ l30-1t model d2fd- @ l30-1h d2fd- @ l30-1t of max. rf min. 0.65 n {66 gf} 0.05 n {5 gf} ot mix. md max. 0.5 mm 0.5 mm fp max. op (-1h) op (-1t) 14.3 mm 11.3 1.0 mm 11.3 1.2 mm t = 0.3 stainless-steel lever r2.5 a 3 4.2 fp op 6.5 0.15
4 d2fd dust proof ultra subminiature basic switch precautions ? refer to general information. degree of protection ? do not use the switch under the environment where it is exposed to water. the degree of protection is ip6x and the protection against water is not defined. ? prevent the switch from coming into contact with oil and chemicals. otherwise, damage to or deterioration of switch materials may result. ? do not use the switch in areas where it is exposed to silicon adhesives, oil, or grease, otherwise faulty contact may result due to the generation of silicon oxide. ? the environment-resistant performance of the switch differs depending on operating loads, ambient atmospheres, and installation conditions, etc. please perform an operating test of the switch in advance under actual usage conditions. terminal connection ? when soldering a lead wire to the terminal, first insert the lead wire conductor into the terminal hole and then perform solder- ing. make sure that the capacity of the soldering iron is 30 w maximum and that the temperature of the soldering iron tip is approximately 300 c. (350 c maximum.) complete the sol- dering within 3 s. using a switch with improper soldering may result in abnormal heating, possibly resulting in burn. applying a soldering iron for more than 3 s or using one that is rated at more than 30 w may deteriorate the switch character- istics. when using automatic soldering baths, we recommend solder- ing at 260 5 c within 5 seconds. make sure that the liquid surface of the solder does not flow over the edge of the board. mounting ? turn off the power supply before mounting or removing the switch, wiring, or performing maintenance or inspection. fail- ure to do so may result in electric shock or burning. ? use m2.3 mounting screws with plane washers or spring wash- ers to securely mount the switch. tighten the screws to a torque of 0.20 to 0.29 n m {2.0 to 2.9 kgf cm}. exceeding the specified torque may result in deterioration of the sealing or damage. mount the switch onto a flat surface. mounting on an uneven surface may cause deformation of the switch, resulting in faulty operation or damage. operating body ? use an operating body with low frictional resistance and of a shape that will not interfere with the sealing rubber, otherwise the plunger may be damaged or the sealing may deteriorate. with the pin plunger models, set the switch so that the plunger can be pushed in from directly above. since the plunger is covered with a rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability. handing ? do not handle the switch in a way that may cause damage to the sealing rubber. ? when handling the switch, ensure that uneven pressure or, as shown in the following diagram, pressure in a direction other than the operating direction is not applied to the actuator, otherwise the actuator or switch may be damaged, or durability may be decreased. using micro loads using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. use models that operate in the following range. however, even when using micro load models within the operating range shown below, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability. therefore, insert a contact protection circuit where necessary. the minimum applicable load is the n-level reference value. this value indicates the malfunction reference level for the reliability level of 60% ( 60). the equation, 60 = 0.5 10 -6 /operations indicates that the estimated malfunction rate is less than 1/ 2,000,000 operations with a reliability level of 60%. cautions correct use correct incorrect incorrect incorrect incorrect incorrect incorrect 30 24 12 5 0 1 10 100 1,000 current (ma) 0.1 1 ma operating range for general-load models d2fd-2 16.6 ma 0.16 ma 100 ma operating range for micro load models d2fd-01 inoperable range voltage (v)
all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0. 03937. to convert grams into ounces, multiply by 0.03527. application examples provided in this document are for reference only. in actual applications, confirm equipment functions and safety before using the product. consult your omron representative before using the product under conditions which are not described in the manual or applying t he product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipm ent, and other systems or equipment that may have a serious influence on lives and property if used improperly. make sure that the ratings and performanc e characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mecha nisms. note: do not use this document to operate the unit. authorized distributor: in the interest of product improvement, specifications are subject to change without notice. cat. no. b119-e1-01 0312 ? omron corporation 2012 all rights reserved. omron corporation electronic and mechanical components company omron electronic components trading (shanghai) ltd. shanghai office 27f xin mei union square, 999 pudong south road, pudong new area, shanghai, china 200120 tel: (86)21-6859-5919/fax: 86-21-6859-5911 omron electronic components europe b.v. wegalaan 57, 2132 jd hoofddorp,the nether lands tel: (31)23-568-1200/fax: 31-23-568-1212 contact: www.omron.com/ecb omron electronic components llc 55 east commerce drive, suite b, il 60173 u.s.a. tel: (1)847-882-2288/fax: 1-847-882-2192 omron electronic components pte ltd. 438a alexandra road #05-05/08 alexandra technopark singapore 119967 tel:(65)6376-3200/fax:(65)6376-3211 omron electronic components co., ltd. 14f, daegong bldg. #823-21, yeoksam-dong, gangnam-gu, seoul, korea, 135-080 tel:(82)2-567-5020/fax:(82)2-567-5804


▲Up To Search▲   

 
Price & Availability of D2FD-01L30-1H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X